Composition of coolant
|
| |
|
| |
2.1 |
Normal case 50 % by volume water 50 % by volume corrosion preventive and antifreezing agent*; antifreeze down to approx. -37 °C
Admissible analysis values: |
| |
|
Sum of alkaline earths (water hardness): |
max. 3,6 mmol/l |
= max. 20° German hardness = max. 36° French hardness = max. 25° British hardness = max. 21° American hardness |
| |
|
| |
|
pH-value at 20 °C: Chlorine ion content: Sum chlorides + sulphates: max. admissible usability:
|
6,5 bis 8,5 max. 100 mg/l max. 200 mg/l 3 years
|
| |
|
| |
2.2 |
Use in frost-proof countries
|
| |
|
Field of application: at permanent ambient temperatures above the freezing point.
90 % by volume water 10 % by volume corrosion preventive additive (coolant additive)**; admissible deviation 1 % by volume
Admissible analysis values:
|
| |
|
Sum of alkaline earths (water hardness): |
max. 2,7 mmol/l |
= max. 15° German hardness = max. 27° French hardness = max. 19° British hardness = max. 16° American hardness |
| |
* ** |
see chapter 4 see chapter 5 |
| |
|
| |
|
pH-value at 20 °C: Chlorine ion content: Sum chlorides + sulphates: max. admissible usability:
|
6,5 bis 8,0 max. 80 mg/l max. 160 mg/l 1 year
|
| |
|
| |
|
Attention: Do not mix corrosion preventive additives with corrosion preventive/antifreezing agent or processing agent! |
| |
|
| |
2.3 |
Exception in frost-proof countries
|
| |
|
Field of application: at permanent ambient temperatures above the freezing point and if provably neither released corrosion preventive and antifreezing agent nor coolant additive are available, the coolant may have the following mixing:
99 % by volume water 1 % by volume processing agent***
Admissible analysis values: |
| |
|
Sum of alkaline earths (water hardness): |
max. 2,7 mmol/l |
= max. 15° German hardness = max. 27° French hardness = max. 19° British hardness = max. 16° American hardness |
| |
|
| |
|
pH-value at 20 °C: Chlorine ion content: Sum chlorides + sulphates: max. admissible usability:
|
6,5 bis 8,0 max. 80 mg/l max. 160 mg/l 6 month
|
| |
|
| |
* |
see chapter 6 |
| |
|
| |
|
For topping up, use an emulsion of 0.5 - 1.0 % by volume. Use 1.5 % by volume in case of new filling or filling after a complete cleaning.
Attention: Too high concentrations (> 1.5 % by volume) have a detrimental effect on sealings and hoses! |