Gateway MVB-CAN

The MVB-CAN gateway converts the process data of the MV bus into the bus messages of the CAN bus and vice versa. The gateway is connected to the VTDC or the VTCsmart via a CAN bus interface.

Technical data:
  • CAN bus interface for communication with VTDC or VTCsmart
  • MV bus class 1.1 coupled with EMD. ESD coupling optional.
  • 16 process data ports with 512 byte traffic storage system
  • Digital and analog inlets and outlets
  • Basic address via hardware coding
  • Assembly in vehicle interior
  • Suitable for ambient temperatures of -25°C to +70°C
  • IP 20
  • Norms: EN 50155, EN 61373, EN 50121-3-2
 